For those other readers who may have overlooked previous comments from Dr Joe, FT4 requires the relative clock difference to not exceed one second, while FT8 is OK at just under 2.4 seconds. If your QSO attempt to another station exceeds those DT maximums, then message decoding suddenly stops. Note that both your spectrum analyzer and waterfall will continue to display the incoming signals.
|
|